E09Boiler & heater codes
Bosch Combi Boiler Error E09 — Flow / Return NTC Sensor Fault
The boiler cannot read a plausible temperature from the flow or return sensor.
Severity: mediumBosch Condens / Class condensing boilersJunkers-Bosch (Bosch Thermotechnik)
Technical meaning
The NTC thermistor on the flow or return line reports a value outside the valid range (open or short circuit).
Symptoms
- No domestic hot water
- Heating stays cold
- Boiler locks out after a few seconds
- Display alternates between E09 and the temperature
Most likely causes
- 1Temperature sensor (NTC) or its wiring is broken or corroded
- 2System pressure below 1 bar, so the sensor measures air instead of water
- 3Air lock or a closed radiator valve blocking circulation
How to fix it
- 1Press and hold the Reset button for about 3 seconds and wait for the restart.
- 2Read the pressure gauge: top the system up to between 1.5 and 2.0 bar with the filling loop.
- 3Open all radiator valves and bleed the radiators to remove trapped air.
- 4Switch the boiler off at the mains, wait 30 seconds, then power it back on.
- 5Check the NTC connector on the PCB for corrosion; reseat it carefully.
- 6If E09 returns immediately after every reset, the sensor must be measured and replaced by a technician.
Reset & basınç kontrolü
1. Reset tuşuna 3 saniye basılı tutun 2. Su basıncını 1.5 - 2.0 bar arasına ayarlayın 3. Kalorifer vanalarının açık olduğunu doğrulayın 4. Cihazı kapatıp 30 saniye bekleyin ve yeniden açın 5. Hata tekrarlarsa servis çağırın
Frequently asked questions
- Can I keep using the boiler with E09?
- No. The boiler blocks heating and hot water to protect the heat exchanger from overheating.
- How much does an NTC sensor cost?
- The part is usually cheap; the labour and the pressure check dominate the bill.